Num
|
Description
|
Operator Action
|
70
|
Hourmeter Failure
|
Report this alarm at the end of the day.
|
71
|
Hourmeter 4 Exceeds Set Time Limit
|
Report this alarm at the end of the day.
|
72
|
Hourmeter 5 Exceeds Set Time Limit
|
Report this alarm at the end of the day.
|
73
|
Hourmeter 6 Exceeds Set Time Limit
|
Report this alarm at the end of the day.
|
74
|
Controller Reset to Defaults
|
Report this alarm at the end of the day.
|
75
|
Controller RAM Failure
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
76
|
Controller EPROM Failure
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
77
|
Controller EPROM Checksum Failure
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
78
|
Data Log EPROM Failure
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
79
|
Internal Data Logger Overflow
|
Report this alarm at the end of the day.
|
80
|
Check Compressor Temp Sensor
|
Report this alarm at the end of the day.
|
81
|
High Compressor Temp
|
Report this alarm at the end of the day.
|
82
|
High Compressor Temp Shutdown
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
83
|
Low Engine Coolant Temp
|
Manually monitor load temperature. Report this alarm at the end of the day.
|
84
|
Restart Null
|
Report this alarm at the end of the day.
|
85
|
Forced Unit Operation
|
Report this alarm at the end of the day.
|
86
|
Check Discharge Pressure Sensor
|
Report this alarm at the end of the day.
|
87
|
Check Suction Pressure Sensor
|
Report this alarm at the end of the day.
|
88
|
Reserved for CR
|
|
89
|
Check Electronic Throttling Valve Circuit
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
90
|
Electric Overload
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
91
|
Check Electric Ready Input
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
92
|
Sensor Grades Not Set
|
Report this alarm at the end of the day.
|
93
|
Low Compressor Suction Pressure
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
94
|
Check Loader #1 Circuit
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
95
|
Check Loader #2 Circuit
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
96
|
Low Fuel Level
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
97
|
Failed Remote Return Air Sensor (CR)
|
Report this alarm at the end of the day.
|
98
|
Check Fuel Level Sensor
|
Report this alarm at the end of the day.
|
99
|
High Compressor Pressure Ratio
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
100*
|
Heater Fan Failure (CR)
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
101
|
Controlling on Evap Coil Outlet Temp (CR)
|
Manually monitor load temperature. Report this alarm at the end of the day. (WAS 94)
|
102*
|
Low Evaporator Coil Temperature (CR)
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
103
|
Low Heater Fuel Level (CR)
|
Manually monitor load temperature. Report this alarm at the end of the day.
|
104
|
Check Remote Fan Speed
|
Manually monitor load temperature. Report this alarm at the end of the day.
|
105
|
Check Receiver Tank Press Sol Circuit
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
106
|
Check Purge Valve Circuit
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
107
|
Check Condenser Inlet Sol Circuit
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|
108
|
Door Open Timeout
|
Close doors. Report this alarm at the end of the day.
|
109
|
Check High Discharge Pressure Sensor
|
Replaced by Alarm Code 86
|
110
|
Check Suction Line Sol Circuit
|
If the unit shuts down on this alarm code repair immediately. Otherwise, report this alarm at the end of the day.
|